Small laser irradiation

This product is a precision optoelectronic device that emits laser light toward a specific target and calculates distance information based on the laser's time-of-flight. It features outstanding performance and simple operation. The laser wavelength is 1064 nm, and direct eye exposure is strictly prohibited. Communication with the host computer is realized via RS422/TTL serial interfaces.

Product Details

Feature

  1. Superior Ranging Capability

  • Maximum range ≥ 5000 m (under visibility ≥ 10 km, 2.3 m × 2.3 m target, reflectivity ≥ 0.2), minimum range ≤ 200 m, covering both long‑distance and medium‑to‑short range scenarios for diverse operational or measurement applications.

  • Ranging accuracy ≤ ±5 m, with a correct ranging rate ≥ 98%, ensuring high data reliability and meeting demanding mission requirements.

  • Stable Laser Illumination Performance

    • Laser wavelength: 1064 nm ± 3 nm; pulse average energy ≥ 25 mJ; pulse energy fluctuation ≤ 10% of the average energy (statistics taken after 2 s of emission), ensuring consistent output per pulse.

    • Divergence angle ≤ 0.6 mrad and optical axis stability ≤ 0.03 mrad guarantee a concentrated beam spot at long distances, high energy efficiency, and clear target identification.

  • Adjustable Ranging/Illumination Frequencies

    • Ranging frequencies: single‑shot, 1 Hz, and 5 Hz; illumination fundamental frequency: 20 Hz, with support for precision frequency coding (45 ms – 56 ms) and external synchronization, coding accuracy ≤ ±2 μs. This flexibility accommodates various application needs for data update rates and synchronization.

    Technical parameters

    No.ItemSpecification
    1Laser Wavelength1064 nm ± 3 nm
    2Transmitting ApertureΦ21 mm
    3Receiving ApertureΦ14 mm
    4Pulse Average Energy≥ 25 mJ
    5Pulse Energy FluctuationWithin one illumination cycle, the single‑pulse energy fluctuation shall not exceed 10% of the average energy (statistics taken after 2 seconds of emission)
    6Divergence Angle≤ 0.6 mrad
    7Laser Optical Axis Stability≤ 0.03 mrad
    8Pulse Width≤ 15 ± 5 ns
    9Power‑on Preparation Time≤ 1 min (over the full temperature range)
    10Ranging CapabilityMinimum range: ≤ 200 m; Maximum range: ≥ 5000 m (Visibility ≥ 10 km, equivalent target 2.3 m × 2.3 m, reflectivity ≥ 0.2, relative humidity ≤ 60%)
    11Ranging FrequencySingle‑shot, 1 Hz, 5 Hz
    12Ranging Accuracy≤ ±5 m
    13Correct Ranging Rate (Probability of correct measurement)≥ 98%
    14Illumination Distance≥ 2 km
    15Illumination FrequencyFundamental frequency 20 Hz
    16Coding MethodPrecision frequency code 45 ms – 56 ms (fundamental 20 Hz), external synchronization
    17Coding Accuracy≤ ±2 μs
    18Illumination ModeLong cycle: operate 60 s, rest 60 s, for 5 consecutive cycles; after that, a 30‑minute interval is required before starting continuous illumination again
    19Overall Dimensions≤ 77 mm × 57 mm × 49 mm (L × W × H)
    20Weight≤ 350 g
    21Communication InterfaceHost‑side connector plug: 151341206 (MOLEX / 600 mm / 12‑pin single‑end); Illuminator‑side connector socket: 530481210 (MOLEX right‑angle 12‑pin)
    22External Synchronization InterfaceHost‑side connector plug: DF52‑4P‑0.8C (200 mm / 4‑pin single‑end); Illuminator‑side connector socket: DF52‑4S‑0.8H (SMD‑4)
    23Baud Rate115200 bps (default) / 460800 / 57600 / 19200 / 38400 bps
    24Supply Voltage18 V ~ 36 V
    25External Synchronization SignalRS422 differential level signal
    26Average Power Consumption≤ 30 W
    27Peak Power Consumption≤ 100 W
    28Start‑up Peak Power Consumption≤ 60 W
    29Standby Power Consumption≤ 5 W
    30Operating Temperature‑40 °C ~ +60 °C
    31Storage Temperature‑55 °C ~ +75 °C
    32Function 1 (Basic Functions)Laser ranging function; provides target laser illumination; communicates with the host computer in accordance with the communication protocol requirements
    33Function 2 (Achievable via communication interface)Responds to laser ranging commands and can stop ranging at any time upon receiving a stop command; during ranging, outputs distance data and status information for each pulse; features range‑gating function; if no instruction is received after starting continuous ranging, it will stop after 5 min (at 1 Hz) or 1 min (at 5 Hz); allows setting of illumination mode and coding; responds to laser illumination commands and illuminates according to the preset mode and coding, and can stop illumination at any time upon receiving a stop command; if no stop command is received after starting illumination, it will automatically stop after one complete cycle; during laser illumination, outputs distance value and status information for each pulse; performs power‑on self‑test and periodic self‑test with status output; responds to self‑test initiation command and outputs status; reports cumulative laser pulse count; first/last target function; signal ground and power ground are isolated from the housing.
    34OthersVibration: refer to GJB 150.16A‑2009, Part 16; Shock: refer to GJB 150.18A‑2009, Part 18

    Note 1: Items marked with an asterisk (*) are design values or theoretical calculated values and are for reference only.

    Note 2: The nominal range and accuracy are achieved under conditions of visibility ≥ 10 km and relative humidity ≤ 60%. The ranging capability and accuracy of the illuminator may vary under different environments and target conditions; actual performance shall be subject to actual measurements. If the illuminator is used on a stable platform, please ensure that the stable platform can achieve stable tracking of the target; otherwise, it may have a certain impact on the illuminator's range or accuracy.